Model CB 260 | CO2 incubators with hot air sterilization and heat sterilizable CO2 sensor
Benefits
- Safe – cell cultures receive maximum protection against contamination
- Reliable – constant well-being conditions for the cells
- Smart – simple routine cleaning and convenient operation
- Economical – efficient operation without consumables
Product description
The powerful and versatile CB CO₂ incubator is suitable for cell-based assays in drug and medical research. This BINDER incubator is even suitable for complex cultivation experiments or individual environments with hypoxic conditions thanks to its comprehensive assortment of options and accessories.
Important characteristics
- Optimized double-pan humidification system with condensation protection
- Tried-and-tested anti-contamination concept with 180°C hot air sterilization
- Hot-air sterilizable CO₂ sensor with single-beam infrared technology
- Seamless inner chamber made of stainless steel with flanges as shelf support system
- Fanless interior with Venturi CO₂ gas mixing nozzle
- Intuitive touchscreen controller
- Internal data recording, can be read out in open format via USB interface
- Fault diagnosis system with visual and acoustic alarm
- Interfaces: Ethernet, USB, zero-voltage alarm contact
- Fail-safe CO₂ system for protecting the pH of cell cultures
Technical specifications
Data | ||||
Designation | CB260-230V | CB260-230V-O | CB260UL-120V | CB260UL-120V-O |
Article Number | 9640-0013 | 9640-0014 | 9640-0015 | 9640-0016 |
Option model | Standard | with O2 control 0.2–20% | Standard | with O2 control 0.2–20% |
Performance Data Temperature | ||||
Temperature range | +5 °C above ambient temperature to 60 °C | +6 °C above ambient temperature to 60 °C | +5 °C above ambient temperature to 60 °C | +6 °C above ambient temperature to 60 °C |
Temperature uniformity at 37°C | 0.4 ± K | 0.4 ± K | 0.4 ± K | 0.4 ± K |
Temperature fluctuation at 37°C | 0.1 ± K | 0.1 ± K | 0.1 ± K | 0.1 ± K |
Recovery time after door was opened for 30 s at 37°C | 6 min | 6 min | 6 min | 6 min |
Performance Data Climate | ||||
Humidity range | 90 ...95 % r.F. | 90 ...95 % r.F. | 90 ...95 % r.F. | 90 ...95 % r.F. |
Gas Data | ||||
CO₂ range | 0 ...20 Vol.-% CO2 | 0 ...20 Vol.-% CO2 | 0 ...20 Vol.-% CO2 | 0 ...20 Vol.-% CO2 |
CO₂ measuring technology | IR | IR | IR | IR |
CO₂ recovery time after door was opened for 30 s at 5 vol. % CO₂ | 5 min | 5 min | 5 min | 5 min |
Standard O₂ control range | 0.2 ...20 Vol.-% O2 | 0.2 ...20 Vol.-% O2 | ||
O₂ control ranges with option: O₂ range | 10 ...90 Vol.-% O2 | 10 ...90 Vol.-% O2 | ||
O₂ recovery time after door was opened for 30 s at 5 vol. % O₂ | 15 min | 15 min | ||
Electrical data | ||||
Rated Voltage | 200...230 V | 200...230 V | 100...120 V | 100...120 V |
Power frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Nominal power | 1,5 kW | 1,5 kW | 1,5 kW | 1,5 kW |
Unit fuse | 10,0 A | 10,0 A | 16,0 A | 16,0 A |
Phase (Nominal voltage) | 1~ | 1~ | 1~ | 1~ |
Dimensions and weights | ||||
Interior volume | 267 L | 267 L | 267 L | 267 L |
Net weight of the unit (empty) | 125 kg | 125 kg | 125 kg | 125 kg |
Load per rack | 10 kg | 10 kg | 10 kg | 10 kg |
Permitted load | 40 kg | 40 kg | 40 kg | 40 kg |
Wall clearance back | 100 mm | 100 mm | 100 mm | 100 mm |
Wall clearance sidewise | 50 mm | 50 mm | 50 mm | 50 mm |
Housing dimensions not incl. fittings and connections | ||||
Width net | 740 mm | 740 mm | 740 mm | 740 mm |
Height net | 1,020 mm | 1,020 mm | 1,020 mm | 1,020 mm |
Depth net | 785 mm | 785 mm | 785 mm | 785 mm |
Internal Dimensions | ||||
Interior width | 620 mm | 620 mm | 620 mm | 620 mm |
Interior height | 750 mm | 750 mm | 750 mm | 750 mm |
Interior depth | 575 mm | 575 mm | 575 mm | 575 mm |
Inner doors | 1 | 1 | 1 | 1 |
Unit doors | 1 | 1 | 1 | 1 |
Environment-specific data | ||||
Sound-pressure level | 41 dB(A) | 41 dB(A) | 41 dB(A) | 41 dB(A) |
Energy consumption at 37°C | 65 Wh/h | 65 Wh/h | 65 Wh/h | 65 Wh/h |
Fixtures | ||||
Number of shelves (std./max.) | 3/8 | 3/8 | 3/8 | 3/8 |