Model KMF 240 | Humidity test chambers with expanded temperature / humidity range
Benefits
- Safe thanks to climatic homogeneity that far exceeds the accuracy required by ICH guidelines as well as THB (85/85), even with a fully loaded unit.
- Reliable thanks to failsafe operation without compromise. The interior and Longlife evaporator plate are made entirely from stainless steel.
- Smart, as a wide range of accessories makes it highly compatible for adaptation to specific customer requirements.
- Economical thanks to maximum effective volume which allows for 30% larger load compared to the competition.
Product description
The BINDER KMF ensures absolutely constant test conditions throughout the testing area. A big advantage of this humidity test chamber is its low space requirement and flexibility in terms of water supply. The wide temperature and humidity range make this humidity test chamber ideally suited for stress testing series.
Important characteristics
- Temperature range: -10 °C to +100 °C
- Humidity range: 10 % RH to 98 % RH
- APT.line™ preheating chamber technology
- Humidity regulation with capacitive humidity sensor and vapor humidification
- Inner chamber made of stainless steel
- BINDER Multi Management Software APT-COM™ Basic Edition
- Intuitive touchscreen controller with time-segment and real-time programming
- Internal data logger, measured values can be read out in open format via USB
- Unit self-test for comprehensive status analysis
- Tight-sealing inner door made of safety glass (ESG)
- Avoidance of glass corrosion by special TIMELESS coating
- 1 stainless steel rack
- Access port with silicone plug, 30 mm, left
- Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
- Computer interface: Ethernet
- Door heating
Technical specifications
Data | ||
Designation | KMF240-230V | KMF240-240V |
Article Number | 9020-0343 | 9020-0344 |
Option model | Standard | Standard |
Performance Data Temperature | ||
Temperature range | -10...100 °C | -10...100 °C |
Average heating-up rate according to IEC 60068-3-5 | 0.8 K/min | 0.8 K/min |
Average cooling down time according to IEC 60068-3-5 | 0.4 K/min | 0.4 K/min |
Performance Data Climate | ||
Temperature range with humidity | 10...90 °C | 10...90 °C |
Humidity range | 10...98 % r.F. | 10...98 % r.F. |
Temperature uniformity with humidity dependent on set value | 0.1...1.0 ± K | 0.1...1.0 ± K |
Temperature fluctuation with humidity dependent on set value | 0.1...0.3 ± K | 0.1...0.3 ± K |
Humidity fluctuation with humidity dependent on set value | ≤2 ± % r.F. | ≤2 ± % r.F. |
Electrical data | ||
Rated Voltage | 200...230 V | 200...240 V |
Power frequency | 50/60 Hz | 50/60 Hz |
Nominal power | 2,1 kW | 2,1 kW |
Unit fuse | 16,0 A | 16,0 A |
Phase (Nominal voltage) | 1~ | 1~ |
Dimensions and weights | ||
Interior volume | 247 L | 247 L |
Net weight of the unit (empty) | 189 kg | 189 kg |
Load per rack | 30 kg | 30 kg |
Permitted load | 100 kg | 100 kg |
Wall clearance back | 100 mm | 100 mm |
Wall clearance sidewise | 100 mm | 100 mm |
Housing dimensions not incl. fittings and connections | ||
Width net | 930 mm | 930 mm |
Height net | 1,465 mm | 1,465 mm |
Depth net | 800 mm | 800 mm |
Internal Dimensions | ||
Interior width | 650 mm | 650 mm |
Interior height | 785 mm | 785 mm |
Interior depth | 485 mm | 485 mm |
Inner doors | 1 | 1 |
Unit doors | 1 | 1 |
Environment-specific data | ||
Sound-pressure level | 52 dB(A) | 52 dB(A) |
Energy consumption at 85°C and 85% RH | 570 Wh/h | 570 Wh/h |
Fixtures | ||
Number of shelves (std./max.) | 1/9 | 1/9 |