Model CB-S 170 | CO2 incubators with hot air sterilization
Benefits
- Safe – cell cultures receive maximum protection against contamination
- Reliable – constant well-being conditions for the cells
- Smart – simple routine cleaning and convenient operation
- Economical – efficient operation without consumables
Product description
The durable and affordable CB-S series incubators are suitable for routine cell cultivation applications in the field of cell production, particularly in academic settings. They are contamination-proof due to 180°C hot air sterilization and reliably pH-stable thanks to the drift-free infrared CO₂ measurements conducted in real time.
Important characteristics
- Temperature range: +6°C above ambient temperature to +50°C
- Humidity range: 90 to 95% RH
- CO₂ control range: 0 to 20 vol.% CO₂
- Tried-and-tested anti-contamination concept with 180°C hot air sterilization
- Humidification system with condensation protection
- CO2 gas mixing jet with Venturi effect
- CO2 sensor with infrared technology
- LCD to display temperature and CO2 along with additional information and alarms
- Internal data logger, measured values can be read out in open format via USB
- Tightly fitted inner door made of safety glass
- Seamless stainless steel inner chamber
- Perforated shelves, stainless steel
- Troubleshooting system with visual and acoustic alarms
- Interfaces: Ethernet, USB, zero-voltage alarm contact
- Units can be stacked with stacking adapters; the CB-S is suitable for stacking with CB and CBF models of the same size
Technical specifications
Data | ||||
Designation | CBS170-230V | CBS170-230V-D | CBS170UL-120V | CBS170UL-120V-D |
Article Number | 9640-0001 | 9640-0029 | 9640-0002 | 9640-0030 |
Option model | Standard | with Access port 30 mm left | Standard | with Access port 30 mm left |
Performance Data Temperature | ||||
Temperature range | +6 °C above ambient temperature to 50 °C | +6 °C above ambient temperature to 50 °C | +6 °C above ambient temperature to 50 °C | +6 °C above ambient temperature to 50 °C |
Temperature uniformity at 37°C | 0.3 ± K | 0.3 ± K | 0.3 ± K | 0.3 ± K |
Temperature fluctuation at 37°C | 0.1 ± K | 0.1 ± K | 0.1 ± K | 0.1 ± K |
Recovery time after door was opened for 30 s at 37°C | 6 min | 6 min | 6 min | 6 min |
Performance Data Climate | ||||
Humidity range | 90 ...95 % RH | 90 ...95 % RH | 90 ...95 % RH | 90 ...95 % RH |
Gas Data | ||||
CO₂ range | 0 ...20 Vol.-% CO2 | 0 ...20 Vol.-% CO2 | 0 ...20 Vol.-% CO2 | 0 ...20 Vol.-% CO2 |
CO₂ measuring technology | IR | IR | IR | IR |
CO₂ recovery time after door was opened for 30 s at 5 vol. % CO₂ | 5 min | 5 min | 5 min | 5 min |
Electrical data | ||||
Rated Voltage | 200...230 V | 200...230 V | 100...120 V | 100...120 V |
Power frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Nominal power | 1,3 kW | 1,3 kW | 1,3 kW | 1,3 kW |
Unit fuse | 10,0 A | 10,0 A | 16,0 A | 16,0 A |
Phase (Nominal voltage) | 1~ | 1~ | 1~ | 1~ |
Dimensions and weights | ||||
Interior volume | 170 L | 170 L | 170 L | 170 L |
Net weight of the unit (empty) | 96 kg | 96 kg | 96 kg | 96 kg |
Load per rack | 10 kg | 10 kg | 10 kg | 10 kg |
Permitted load | 30 kg | 30 kg | 30 kg | 30 kg |
Wall clearance back | 100 mm | 100 mm | 100 mm | 100 mm |
Wall clearance sidewise | 50 mm | 50 mm | 50 mm | 50 mm |
Housing dimensions not incl. fittings and connections | ||||
Width net | 680 mm | 680 mm | 680 mm | 680 mm |
Height net | 870 mm | 870 mm | 870 mm | 870 mm |
Depth net | 715 mm | 715 mm | 715 mm | 715 mm |
Internal Dimensions | ||||
Interior width | 560 mm | 560 mm | 560 mm | 560 mm |
Interior height | 600 mm | 600 mm | 600 mm | 600 mm |
Interior depth | 505 mm | 505 mm | 505 mm | 505 mm |
Inner doors | 1 | 1 | 1 | 1 |
Unit doors | 1 | 1 | 1 | 1 |
Environment-specific data | ||||
Sound-pressure level | 41 dB(A) | 41 dB(A) | 41 dB(A) | 41 dB(A) |
Energy consumption at 37°C | 45 Wh/h | 45 Wh/h | 45 Wh/h | 45 Wh/h |
Fixtures | ||||
Number of shelves (std./max.) | 2/6 | 2/6 | 2/6 | 2/6 |