Model WIC 3 | Walk-in-chambers for stability testing according to ICH (Q1A) 

Benefits
  • Stable and uniform environment
  • Fully complies with Pharma regulations (ICH)Equipment
  • Longevity - corrosion resistant
  • Ease of operation
  • Environmental friendly refrigerant with GWP value 547
  • Maintenance possible with the least possible disruption to the climate conditioning
  • Perfectly meets requirements in Pharma industry
  • 3 years warranty

Configure your product with options and accessories and request it directly here.

Product description

The walk-in-chambers offer a wide range of features and benefits to perfectly meet requirements in stability testing. Perfect test conditions are maintained in a wide range of temperature from 10°C to 50°C and relative humidity of 20% to 90% RH.

Important characteristics

  • Relative humidity accuracy of ± 2.5%
  • Temperature accuracy of ± 1.5°C
  • Duct work for proper distribution of air
  • Highly insulated room panels with U value of only 0,21 W/m2K
  • LED Lighting with motion detector
  • High quality room elements, made in Germany
  • Interior completely stainless steel
  • Exterior service accessibility
  • Room Elements: Galvanized sheet steel, polyester coated, white, similar to RAL 9010, interior surfaces in stainless steel,
    4 inch / 100 mm PU foam U value: 0,21W/m2K
  • Floor: Floor overlay is chrome-nickel steel, pattern-rolled 5WL
  • Surface load: 50.000 N/m2

Technical specifications

Data
Designation

WIC3-230V

WIC3-208V

WIC3C-208V

Article Number9800-00139800-00079800-0008
Option model

Standard

Standard

with conditioner on ceiling

Performance Data Temperature
Temperature range{3299}...{3298}{3299}...{3298}{3299}...{3298}
Performance Data Climate
Temperature range with humidity10...50 °C10...50 °C10...50 °C
Humidity range20...90 % RH20...90 % RH20...90 % RH
Temperature uniformity at 25°C and 60% RH1.5 ± K1.5 ± K1.5 ± K
Temperature uniformity at 40°C and 75% RH1.5 ± K1.5 ± K1.5 ± K
Temperature fluctuation at 25°C and 60% RH0.5 ± K0.5 ± K0.5 ± K
Temperature fluctuation at 40°C and 75% RH0.5 ± K0.5 ± K0.5 ± K
Electrical data
Rated Voltage230 V208...230 V208...230 V
Power frequency50 Hz60 Hz60 Hz
Nominal power2,7 kW2,7 kW2,7 kW
Unit fuse20,0 A20,0 A20,0 A
Phase (Nominal voltage)1~1~1~
Dimensions and weights
Interior volume24,516 L24,516 L24,516 L
Net weight of the unit (empty)1,186 kg1,186 kg1,186 kg
Housing dimensions not incl. fittings and connections
Width net2,600 mm2,600 mm2,600 mm
Height net2,470 mm2,470 mm2,470 mm
Depth net4,700 mm4,700 mm4,700 mm
Internal Dimensions
Interior width2,400 mm2,400 mm2,400 mm
Interior height2,270 mm2,270 mm2,270 mm
Interior depth4,500 mm4,500 mm4,500 mm
Unit doors111
Environment-specific data
Energy consumption at 40°C and 75% RH1,150 Wh/h1,150 Wh/h1,150 Wh/h